{"id":627,"date":"2023-11-29T07:28:25","date_gmt":"2023-11-29T07:28:25","guid":{"rendered":"https:\/\/test.metrosemi.com\/?page_id=627"},"modified":"2023-12-14T12:37:48","modified_gmt":"2023-12-14T12:37:48","slug":"f50-series","status":"publish","type":"page","link":"https:\/\/test.metrosemi.com\/?page_id=627","title":{"rendered":"F50 SERIES"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"627\" class=\"elementor elementor-627\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c534d81 e-flex e-con-boxed e-con e-parent\" data-id=\"c534d81\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-ab3009b e-con-full e-flex e-con e-child\" data-id=\"ab3009b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf8aaea elementor-widget elementor-widget-text-editor\" data-id=\"bf8aaea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>F20 Series Film Thickness Measurement Instruments<\/strong><\/h3><div class=\"row row1\"><div class=\"col-sm-6\">F20s are general-purpose film thickness measurement instruments, and are used in thousands of applications worldwide. Thickness and refractive index can be measured in less than a second. Like all of our thickness measurement instruments, the F20 connects to the USB port of your Windows\u00ae computer and sets up in minutes.<br \/><br \/>The different F20 instruments are distinguished primarily by the thickness measurement range, which in turn is determined by the instrument&#8217;s wavelength range. The standard F20 is our most popular product.<\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-466f785 e-con-full e-flex e-con e-child\" data-id=\"466f785\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa14ae5 elementor-widget elementor-widget-image\" data-id=\"fa14ae5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"700\" height=\"466\" src=\"https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/01.jpg\" class=\"attachment-large size-large wp-image-878\" alt=\"\" srcset=\"https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/01.jpg 700w, https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/01-300x200.jpg 300w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-afb2634 e-flex e-con-boxed e-con e-parent\" data-id=\"afb2634\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8c01cb2 e-con-full e-flex e-con e-child\" data-id=\"8c01cb2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf5c7d3 elementor-widget elementor-widget-text-editor\" data-id=\"bf5c7d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>F50 Film Thickness Measurement Mapping Instrument<\/strong><\/h3><div class=\"row row1\"><div class=\"col-sm-6\">Automated Film Thickness Mapping.The F50 family of products can map film thickness as quickly as two points per second. A motorized R-Theta stage accepts standard and custom chucks for samples up to 450mm in diameter. (This is the same high-lifetime stage that performs millions of measurements in our production systems!) Map patterns can be polar, rectangular, or linear, or you can create your own with no limit on the number of measurement points. Dozens of pre-defined map patterns are supplied. The F50 film thickness mapping system connects to the USB port of your Windows\u00ae computer and can be set up in minutes. The different F50 instruments are distinguished primarily by thickness and wavelength range. The standard F50 is the most popular. Generally shorter wavelengths (e.g. F50-UV) are required for measurement of thinner films, while longer wavelengths allow measurement of thicker, rougher, and more opaque films.<\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0a69267 e-con-full e-flex e-con e-child\" data-id=\"0a69267\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ed405cb elementor-widget elementor-widget-image\" data-id=\"ed405cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"244\" src=\"https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/02-1-300x244.png\" class=\"attachment-medium size-medium wp-image-879\" alt=\"\" srcset=\"https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/02-1-300x244.png 300w, https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/02-1.png 443w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-86a2b52 e-flex e-con-boxed e-con e-parent\" data-id=\"86a2b52\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a38a212 elementor-widget elementor-widget-image\" data-id=\"a38a212\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"396\" src=\"https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/04-1-1024x396.png\" class=\"attachment-large size-large wp-image-881\" alt=\"\" srcset=\"https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/04-1-1024x396.png 1024w, https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/04-1-300x116.png 300w, https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/04-1-768x297.png 768w, https:\/\/test.metrosemi.com\/wp-content\/uploads\/2023\/12\/04-1.png 1205w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>F20 Series Film Thickness Measurement Instruments F20s are general-purpose film thickness measurement instruments, and are used in thousands of applications worldwide. Thickness and refractive index can be measured in less than a second. Like all of our thickness measurement instruments, the F20 connects to the USB port of your Windows\u00ae computer and sets up in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-627","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=\/wp\/v2\/pages\/627","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=627"}],"version-history":[{"count":7,"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=\/wp\/v2\/pages\/627\/revisions"}],"predecessor-version":[{"id":887,"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=\/wp\/v2\/pages\/627\/revisions\/887"}],"wp:attachment":[{"href":"https:\/\/test.metrosemi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}